Make Alloy resilient to transient failures; remove leftover Grafana (PESO-149)

copenhagen-c stopped reporting to Grafana Cloud on 2026-05-20: a transient
TLS failure to fleet-management tripped systemd's default start rate-limit,
systemd gave up, and the host sat silently unmonitored for ~2.5 weeks.

Add a 10-resilience.conf systemd drop-in for alloy.service on every host
(StartLimitIntervalSec=0, Restart=always, RestartSec=30) so a momentary
upstream/TLS blip can no longer permanently kill the collector.

Also drop the old self-hosted Grafana package that was left enabled and
failing on copenhagen-c after the move to Grafana Cloud.
This commit is contained in:
Rasmus Wejlgaard 2026-06-07 14:06:03 +01:00
parent 81efa1b717
commit 3702584856
3 changed files with 63 additions and 0 deletions

View file

@ -11,3 +11,9 @@
- name: Reload systemd daemon
ansible.builtin.systemd:
daemon_reload: true
- name: Restart alloy
ansible.builtin.systemd:
name: alloy
state: restarted
daemon_reload: true

View file

@ -162,3 +162,58 @@
name: cloudflared
state: absent
purge: true
# --- Grafana Alloy: restart resilience (PESO-149) ---
# Every host runs alloy.service to ship metrics/logs to Grafana Cloud. On
# 2026-05-20 a transient TLS failure to Grafana fleet-management tripped
# systemd's default start rate-limit on copenhagen-c; systemd then gave up and
# the host went silently unmonitored for ~2.5 weeks. Disable the rate limit so
# Alloy keeps retrying indefinitely, backing off 30s between attempts, instead
# of dying permanently on a momentary blip.
- name: Check for Alloy unit
ansible.builtin.stat:
path: /lib/systemd/system/alloy.service
register: common_alloy_unit
- name: Install Alloy systemd resilience drop-in
ansible.builtin.copy:
dest: /etc/systemd/system/alloy.service.d/10-resilience.conf
mode: '0644'
content: |
# Managed by Ansible (pez-infra) — common role, PESO-149.
# Keep Alloy retrying through transient upstream/TLS failures instead of
# hitting systemd's start rate-limit and giving up.
[Unit]
StartLimitIntervalSec=0
[Service]
Restart=always
RestartSec=30
when: common_alloy_unit.stat.exists | default(false)
notify: Restart alloy
# --- Cleanup: leftover self-hosted Grafana (PESO-149) ---
# Monitoring moved fully to Grafana Cloud, but the old Grafana OSS package was
# never removed from copenhagen-c, where grafana-server.service sits enabled
# and failing. Remove it wherever it lingers (no-op on every other host).
- name: Detect leftover grafana-server unit
ansible.builtin.stat:
path: /lib/systemd/system/grafana-server.service
register: common_grafana_unit
- name: Remove leftover self-hosted Grafana
when: common_grafana_unit.stat.exists | default(false)
block:
- name: Stop and disable grafana-server
ansible.builtin.systemd:
name: grafana-server
state: stopped
enabled: false
failed_when: false
- name: Uninstall grafana package
ansible.builtin.apt:
name: grafana
state: absent
purge: true
notify: Reload systemd daemon

View file

@ -30,6 +30,8 @@ Alloy runs as `alloy.service` on every host in the inventory. Each host is regis
Pipelines (what to scrape, how to relabel, where to ship) live in `terraform/grafana/fleet_pipelines/` and are pushed to Grafana Cloud as a `grafana_fleet_management_pipeline` resource. The Alloy daemons on each host pull their config from Fleet Management.
The `common` role drops a `10-resilience.conf` systemd override onto every host (`StartLimitIntervalSec=0`, `Restart=always`, `RestartSec=30`) so a transient upstream/TLS failure can't trip systemd's start rate-limit and permanently kill the collector — it keeps retrying until Grafana Cloud is reachable again. (Added after copenhagen-c sat unmonitored for ~2.5 weeks following one such blip — PESO-149.)
### Local exporters scraped by Alloy
| Exporter | Hosts | What |