mirror of
https://github.com/RWejlgaard/pez-infra.git
synced 2026-07-04 15:46:16 +00:00
Make Alloy resilient to transient failures; remove leftover Grafana (PESO-149)
copenhagen-c stopped reporting to Grafana Cloud on 2026-05-20: a transient TLS failure to fleet-management tripped systemd's default start rate-limit, systemd gave up, and the host sat silently unmonitored for ~2.5 weeks. Add a 10-resilience.conf systemd drop-in for alloy.service on every host (StartLimitIntervalSec=0, Restart=always, RestartSec=30) so a momentary upstream/TLS blip can no longer permanently kill the collector. Also drop the old self-hosted Grafana package that was left enabled and failing on copenhagen-c after the move to Grafana Cloud.
This commit is contained in:
parent
81efa1b717
commit
3702584856
3 changed files with 63 additions and 0 deletions
|
|
@ -11,3 +11,9 @@
|
|||
- name: Reload systemd daemon
|
||||
ansible.builtin.systemd:
|
||||
daemon_reload: true
|
||||
|
||||
- name: Restart alloy
|
||||
ansible.builtin.systemd:
|
||||
name: alloy
|
||||
state: restarted
|
||||
daemon_reload: true
|
||||
|
|
|
|||
|
|
@ -162,3 +162,58 @@
|
|||
name: cloudflared
|
||||
state: absent
|
||||
purge: true
|
||||
|
||||
# --- Grafana Alloy: restart resilience (PESO-149) ---
|
||||
# Every host runs alloy.service to ship metrics/logs to Grafana Cloud. On
|
||||
# 2026-05-20 a transient TLS failure to Grafana fleet-management tripped
|
||||
# systemd's default start rate-limit on copenhagen-c; systemd then gave up and
|
||||
# the host went silently unmonitored for ~2.5 weeks. Disable the rate limit so
|
||||
# Alloy keeps retrying indefinitely, backing off 30s between attempts, instead
|
||||
# of dying permanently on a momentary blip.
|
||||
- name: Check for Alloy unit
|
||||
ansible.builtin.stat:
|
||||
path: /lib/systemd/system/alloy.service
|
||||
register: common_alloy_unit
|
||||
|
||||
- name: Install Alloy systemd resilience drop-in
|
||||
ansible.builtin.copy:
|
||||
dest: /etc/systemd/system/alloy.service.d/10-resilience.conf
|
||||
mode: '0644'
|
||||
content: |
|
||||
# Managed by Ansible (pez-infra) — common role, PESO-149.
|
||||
# Keep Alloy retrying through transient upstream/TLS failures instead of
|
||||
# hitting systemd's start rate-limit and giving up.
|
||||
[Unit]
|
||||
StartLimitIntervalSec=0
|
||||
|
||||
[Service]
|
||||
Restart=always
|
||||
RestartSec=30
|
||||
when: common_alloy_unit.stat.exists | default(false)
|
||||
notify: Restart alloy
|
||||
|
||||
# --- Cleanup: leftover self-hosted Grafana (PESO-149) ---
|
||||
# Monitoring moved fully to Grafana Cloud, but the old Grafana OSS package was
|
||||
# never removed from copenhagen-c, where grafana-server.service sits enabled
|
||||
# and failing. Remove it wherever it lingers (no-op on every other host).
|
||||
- name: Detect leftover grafana-server unit
|
||||
ansible.builtin.stat:
|
||||
path: /lib/systemd/system/grafana-server.service
|
||||
register: common_grafana_unit
|
||||
|
||||
- name: Remove leftover self-hosted Grafana
|
||||
when: common_grafana_unit.stat.exists | default(false)
|
||||
block:
|
||||
- name: Stop and disable grafana-server
|
||||
ansible.builtin.systemd:
|
||||
name: grafana-server
|
||||
state: stopped
|
||||
enabled: false
|
||||
failed_when: false
|
||||
|
||||
- name: Uninstall grafana package
|
||||
ansible.builtin.apt:
|
||||
name: grafana
|
||||
state: absent
|
||||
purge: true
|
||||
notify: Reload systemd daemon
|
||||
|
|
|
|||
|
|
@ -30,6 +30,8 @@ Alloy runs as `alloy.service` on every host in the inventory. Each host is regis
|
|||
|
||||
Pipelines (what to scrape, how to relabel, where to ship) live in `terraform/grafana/fleet_pipelines/` and are pushed to Grafana Cloud as a `grafana_fleet_management_pipeline` resource. The Alloy daemons on each host pull their config from Fleet Management.
|
||||
|
||||
The `common` role drops a `10-resilience.conf` systemd override onto every host (`StartLimitIntervalSec=0`, `Restart=always`, `RestartSec=30`) so a transient upstream/TLS failure can't trip systemd's start rate-limit and permanently kill the collector — it keeps retrying until Grafana Cloud is reachable again. (Added after copenhagen-c sat unmonitored for ~2.5 weeks following one such blip — PESO-149.)
|
||||
|
||||
### Local exporters scraped by Alloy
|
||||
|
||||
| Exporter | Hosts | What |
|
||||
|
|
|
|||
Loading…